prof.logo

Elbi ACGPM-25 Hydrophore 24l Horizontal, Red (770010)

SKU
164516
Ean
8019742012075
Special Price €40,98 was €60,31
In stockIn supplier's warehouse 30 pcs
Elbi ACGPM-25 Hydrophore 24l Horizontal, Red (770010)
€40,98
Shipping methods:
Self-pickup - Ganību dambis 25D | FREE
Receive from 22. till 23. November
Self-pickup | Not available
Delivery by courier | from €10.99
Receive from 25. till 28. November
Delivery by courier | From 10kgDelivery by courier | Not available
CONVENIENT SHOPPING
CONVENIENT SHOPPING
70.000+ PRODUCTS
100.000+
PRODUCTS
DELIVERY ALL OVER LATVIA
DELIVERY ALL OVER LATVIA
CLIENT SUPPORT
CLIENT SUPPORT

More Information

Manufacturer
Elbi
Model
ACGPM-25
Location
Horizontāls
Type
Hidrofors
Volume (l)
24l
Diameter (cm)
27cm
Height (cm)
29cm
Connection
1''
Operating temperature (°C)
-10 - 99ºC
Color
Sarkana
Svītrkods
8019742012075

Details

ELBI ACGPM-25 horizontal hydrophore

Horizontal pressure vessel with a diaphragm pump; factory pre-charged air pressure 1.5bar, Operating temperature from -10C to +99C, Available in red or blue color,

Do not exceed the maximum working pressure and temperature of the expansion tank; ensure the system has appropriate control to prevent exceeding these parameters,Provide a suitable drainage system that prevents extensive damage in case of a crack and water leakage from the expansion tank,


When installing, provide a proper water and air leakage system,The manufacturer is not responsible for external forces (traffic, wind, earthquakes) affecting the expansion tank, so it should be evaluated before installation,Clarify the main parameters of the system before installation,Qualified personnel should regularly check this system,The manufacturer is not liable for any damages resulting from incorrect installation of the equipment,If the maximum working pressure and temperature of the expansion tank are exceeded, the manufacturer has the right to refuse warranty claims,If different fluids are used in the system, check their compatibility,The installation site must be protected from unauthorized personnel - only authorized personnel are allowed in this area,The equipment must be equipped with proper grounding or isolated from the heating system with a dielectric connection,

If the hydrophore is installed in an existing system, make sure the pump control panel has no power supply and the system is completely drained or the water supply is closed,2, If a simple pressure vessel (without a membrane) is installed in the existing system, turn off the air supply devices, level indicators, etc.,3, Remove the tank from the packaging, remove the protective cap (see, 4, no, 6) from the air valve, Check the existing pressure and make sure it is slightly lower than the pressure at which the pressure switch operates, If necessary, adjust the pressure in the tank, Once done, screw the protective cap back on,4, Install the tank as close as possible to the pressure switch to minimize pressure losses, Examples of tank installation are shown in figures 1, 2, and 3,5, Connect the tank to the main water pipe or to the pump outlet, following all installation rules,6, It is recommended to install a safety valve and adjust it according to the maximum working pressure of the system,7, Connect the power supply to the pump control panel only after the tank installation is completed,8, Turn on the pump and fill the system with water until the pressure switch operates and the pump turns off,9, To vent the system, repeatedly open and close the faucet farthest from the tank, 10, Open one or more faucets to empty the tank, If a pause is detected between emptying the tank and turning on the pump, either slightly increase the pressure switch activation pressure or reduce the air pressure in the pressure vessel (see point 3),11, Repeat steps 8, 9, and 10 until this pause is no longer detected,12, Check all connections and make sure there is no water leakage from them,13, The system is ready for use if all the above points have been successfully completed,14, Regularly check the existing pressure in the tank during its operation and fill it with air if necessary,When performing maintenance, first turn off all electrical equipment related to the system and check that there is no pressure and temperature hazardous to health in the system, Qualified personnel should check all heating system elements at least once a year, The manufacturer has already pre-charged the air in the pressure vessel, Changes in air pressure in the expansion tank should only be done by a certified plumber, The newly set pressure should be recorded on the expansion tank,

*Translated using automatic translation tool

Reviews

Write a review for: Elbi ACGPM-25 Hydrophore 24l Horizontal, Red (770010)