prof.logo

Vents Twinfresh Comfo RB1-50 Wall-mounted Heat Recovery Ventilator, RB1-85-2, 84148080

SKU
269143
Ean
CEG071
Special Price €331,54 was €387,20
Out of stock
Vents Twinfresh Comfo RB1-50 Wall-mounted Heat Recovery Ventilator, RB1-85-2, 84148080
Shipping methods:
Self-pickup - Ganību dambis 25D |
Receive from 27. May till 4. June
Self-pickup | Not available
CONVENIENT SHOPPING
CONVENIENT SHOPPING
70.000+ PRODUCTS
100.000+
PRODUCTS
DELIVERY ALL OVER LATVIA
DELIVERY ALL OVER LATVIA
CLIENT SUPPORT
CLIENT SUPPORT

More Information

Manufacturer
Vents
Collection
Twinfresh Comfo RB1-50
Type
Horizontāls
Air duct diameter (mm)
160mm
Diameter (mm)
20mm
Filter class
G3
Energy efficiency class
A
Productivity (m³/h)
54
Location
Sienas
Effectiveness
88%
Yield m3/h
54m³/h
Height (cm)
30
Width (cm)
28
Depth (cm)
42.5
Noise level
40dB
Weight (kg)
6.3kg
Svītrkods
CEG071

Details

Energy is recovered due to reversing operation of the ventilator, which consists of two cycles:

CYCLE I. Warm stale air is extracted from the room, then it passes through the ceramic energy accumulator and while flowing through it, heats and moistens the ceramic accumulator transferring up to 88 % of its thermal energy. In 70 seconds, as the ceramic heat exchanger gets heated, the ventilator switches to supply mode automatically.
CYCLE II. Clean fresh air from outside passes through the ceramic energy accumulator, absorbs moisture and is heated up to the room temperature due to the accumulated heat. In 70 seconds, as temperature of the accumulator drops down, the fan switches to extract mode and the cycle is renewed.
The ventilator changes its operation mode between supply and extract ventilation every 70 seconds.

  • Supply clean fresh air to the premises
  • Remove stale extract air from the premises
  • Clean the air of dust and insects
  • Prevent penetration of excessive humidity and appearance of mould
  • Protect against outdoor noise
  • Recover heat and provide humidity balance inside
  • Reduce the heating costs in winter and air conditioning costs in summer
  • Low energy demand

VENTILATION SYSTEM ARRANGEMENT EXAMPLE BASED ON TWINFRESH VENTILATORS

  • To arrange a ventilation system based on TwinFresh ventilators, install one ventilator in each room.
  • For larger premises, install two or more ventilators.
  • It is advisable to use paired units to ensure balanced ventilation.
  • While integrating many ventilators into a single network one part of them must be set into air supply mode and the other part must be set into air extract mode.
  • TwinFresh ventilators are also suitable for use as single units.
  • Operation mode of each ventilator installed in a separate room is individually adjustable.
  • Air flows from one room to another through door grilles, openings or halls and provides that way required circulation in a premise.
  • An energy regeneration ventilation system based on the TwinFresh ventilators is designed to save operating costs for heating and air conditioning.
  • To arrange the most energy efficient ventilation in a kitchen or in a bathroom we recommend to install in the kitchen or in the bathroom the intelligent VENTS iFans that extract air on a signal from the activated motion or humidity sensor.

Ceramic energy accumulator (regenerator).

The high-tech ceramic energy accumulator with regeneration efficiency up to 88 % is used for extract air heat energy recovery and supply air heating. Due to its cellular structure, the unique energy accumulator has larger air contact area and excellent heat conducting and accumulating properties. The ceramic energy accumulator has a special anti-bacterial treatment to prevent bacteria generation inside of the regenerator. The antibacterial treatment is rated for 10 years operation. The outer side of the regenerator is lined up with a heat insulating material.

Reversible DC fan.

Air is supplied or extracted by a reversible axial fan with DC motor with safe voltage 12 V. Due to DC technology the fan is distinguished with low energy demand. The motor has overheating protection and ball bearings for longer service life. 

Outer ventilation hood.

The specially designed outer hood enables removal of extract air flow and condensate that is generated inside of the outer hood from the building wall. Besides, the outer hood prevents ingress of water and foreign objects in the ventilator. The outer hood is internally covered with insulating material that absorbs street noise penetration into the room through the ventilator and prevents condensate generation in the outer hood. The EH 150 outer hood is made of polymer coated aluminium. The EH-2 150 outer hood for thin walls is made of polymer coated stainless steel. Due to its labyrinth structure of the outer hood air flow changes its direction several times and the ventilator is protected against direct wind impact.

Mounting plate

The TwinFresh Comfo series models are equipped with a mounting plate which facilitates servicing of the fans, filters and the regenerator. The ventilation unit is fixed to the mounting plate with special magnets and contact sockets. The ventilator inner parts are accessible by pulling the ventilation unit by hand.

*Translated using automatic translation tool

Reviews

Write a review for: Vents Twinfresh Comfo RB1-50 Wall-mounted Heat Recovery Ventilator, RB1-85-2, 84148080