Electrical performance
Low Voltage: 1,5/1,5 1kV · (1,8) kV DC. 1,0/1,0 kV · (U0/U).
Standard
EN 50618/ IEC 62930 / UTE C 32-502.
Approvals
TÜV / RETIE / CE / RoHS.
CPR Construction Product Regulation
Cca -s1b, d2, a1.
Water performance
Water presence: AD8 submerged.
Estimated Lifetime
Estimated lifetime 30 years based on EN 50618.
Applications
Solar PV installations.
TOPSOLAR PV H1Z2Z2-K Cable Design
- Conductor: Class 5 (flexible) tinned copper, based on EN 60228 and IEC 60228.
- Insulation: Low smoke halogen Free (LSHF) rubber.
- Outer sheath: Low smoke halogen Free (LSHF) rubber, red or black colour.
Thermal performance
- Maximum service temperature: 120ºC.
- Maximum short-circuit temperature: 250ºC (max. 5 s).
- Minimum service temperature: -40ºC (fixed and protected installations).
Fire performance
- Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.
- LSHF (Low Smoke Halogen Free) based on UNE-EN 60754-1 and IEC 60754-1.
- Low smoke emission based on UNE-EN 61034 and IEC 61034: Light transmittance > 60%.
- Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.
- Reaction to fire CPR: Cca -s1b, d2, a1, according to EN 50575.
Mechanical performance
- Minimum bending radius: x5 cable diameter.
- Impact resistance: AG2 Medium severity.
Chemical performance
- Chemical & Oil resistance: Excellent.
- Grease & mineral oils resistance: Excellent.
- Ozone resistant based on EN 50618.
- UV Resistant based on EN 50618.
Other
- Meter by meter marking.
- Optional: rodent-proof and termite-proof.
Installation conditions
- Open Air.
- Buried.
- In conduit.